Parties and non-human actors — named on records, never sign in
The other six actors in PORTAL-ROLES §2. None of them opens the portal, so none has a feature file of its own — but each imposes requirements on the roles that do, and those requirements are listed here so the folder covers all sixteen actors rather than the ten with logins.
Rita is the exception in this file. She is listed here because she is not a user — but unlike the other five, there is one of her per user, so her requirements are per-role and each role file carries them. See PORTAL-ROLES §3.4.
The rule that generates this file: *an identity in the record is not a
login.* A crew member who did the work, a site representative who countersigned
on a phone, a regulator receiving a notifiable report — all must be nameable
on a record without ever holding an account. Requiring a login in order to be
named is exactly how a system ends up recording "device".
P1 · Site representative
Countersigns a walk on the inspector's device — the client's or the site's person, present at the time, whoever that is on the day.
| ID | Requirement | On whom | Today |
|---|---|---|---|
| F-PTY-1 | Nameable and signable on the inspector's device, with no account | field inspector | ✅ two-party signature exists (apps/esg-field/screens/SignoffSheet.tsx:45) |
| F-PTY-2 | The signature survives identity landing — adding accounts must not turn a two-party signature into a one-party one | platform | ⚠️ risk at F-INS-1 |
| F-PTY-3 | Their name is captured as typed by them, with the role they signed as (BR-S5) | field inspector | ✅ |
P2 · Crew, operator or vendor
Performs corrective work. Almost never has a login and frequently is not our employee.
| ID | Requirement | On whom | Today |
|---|---|---|---|
| F-PTY-4 | Nameable as the performer on a corrective action, distinct from the user who recorded it | site supervisor (F-SUP-2) | ❌ |
| F-PTY-5 | The performer/recorder distinction is what makes self-verification disclosure meaningful — without it, BR-CA7 cannot be evaluated | env manager (F-MGR-6) | ❌ |
| F-PTY-6 | Dates recorded are when the work was done, not when it was typed (BR-CA8) | site supervisor | ❌ |
P3 · Regulator — MECP, TRCA
Never a user, in any form. The ultimate consumer of a notifiable-incident report, and the reason several clocks exist.
| ID | Requirement | On whom | Today |
|---|---|---|---|
| F-PTY-7 | A notifiable incident carries a deadline a named person is accountable for closing (BR-I4) | director (F-DIR-4) | ❌ no clock exists |
| F-PTY-8 | Occurred-at and reported-at are both captured and never conflated (BR-I3) | supervisor (F-SUP-5) | ❌ |
| F-PTY-9 | What was sent to the regulator, by whom and when, is a release decision with an author (FR-ROLE-14) | director (F-DIR-5) | ❌ |
| F-PTY-10 | Permits name their issuer as an authority, not as a user — issuer: "MECP · EASR" is already the data shape (app/lib/permits.ts:46) | — | ✅ |
P4 · Board / JV board
Receives a quarterly pack. Governance, not operations.
| ID | Requirement | On whom | Today |
|---|---|---|---|
| F-PTY-11 | The board pack is a cut of one record, not a separately-authored document — one derivation, four renderers (boardroom §2) | director (F-DIR-5) | ❌ |
| F-PTY-12 | Releasing it is the same release decision as any other external release; the role model decides who may release a cut, never who may author a different one | director | ❌ |
N1 · Rita — one per person, not one for the system
Rita is each individual's agent. There are as many instances of her as there are users: the inspector's Rita, the manager's Rita, the client rep's Rita. Each role file in this folder has a "Their Rita" section saying what that instance does. None of them holds a grant. Ever. This is the row most likely to be given authority by accident, which is why it is written down.
| ID | Requirement | Today |
|---|---|---|
| F-PTY-13 | May draft, summarise, rank and propose. May not mark coverage, sign, submit, close a ticket, assign an owner, or supply a value no person or sensor produced (FR-UX-9, BR-U4) | ✅ enforced in CI by scripts/guard-no-llm-in-proof-chain.mjs |
| F-PTY-14 | Generated content is labelled a draft and is a person's to accept or edit; the original media, the original transcript, the human edit and the accepted record stay separately recoverable (BR-U4) | ⚠️ |
| F-PTY-15 | An accepted draft is attributed to the human who accepted it, never to the model | ❌ needs identity |
| F-PTY-19 | Each instance reads with its principal's scope claim — never a service identity, never a superset (FR-ROLE-19). An agent that sees more than the person it answers to is a scope leak, and a service token is the convenient way to build one by accident | ❌ |
| F-PTY-20 | Memory and conversation recall are per-identity (FR-ROLE-20). One person's exchanges never surface in another's — the client rep's instance is the sharpest case (app/lib/conversations.ts is currently one shared history) | ❌ |
| F-PTY-21 | No basis ⇒ she says so, rather than composing a plausible answer. Already the shipped discipline: answers are briefed or on-device, each with a provenance chip, and the field app's Rita calls no network and holds no model key (apps/esg-field/screens/Rita.tsx) | ✅ on device |
N2 · The device
A device is a bearer of a key, not an actor.
| ID | Requirement | Today |
|---|---|---|
| F-PTY-16 | The device attests where and when a record was captured. It never attests who — that is the person's credential, bound at sign-in (FR-ROLE-16) | ❌ inspectorId: "device" (apps/esg-field/screens/inspect/TaskFlow.tsx:262) |
| F-PTY-17 | A lost device is revocable without touching the records it already produced (F-ADM-3, F-ADM-4) | ❌ |
| F-PTY-18 | Delivery from a device is reported as delivered only where delivery was observed (BR-X5, FR-X-6) | ✅ in apps/esg-field/lib/ncr/api.ts |
Traceability
BR-S5 · BR-CA7/CA8 · BR-I3/I4 · BR-U4 · BR-X5 · FR-UX-9 · FR-SEC-5 · FR-X-6 · FR-ROLE-1/14/16/17 · PORTAL-ROLES §2, §6.11